<?xml version='1.0' encoding='UTF-8'?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-03-14T23:29:24Z</responseDate>
  <request metadataPrefix="oai_dc" identifier="oai:kait.repo.nii.ac.jp:00001056" verb="GetRecord">https://kait.repo.nii.ac.jp/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:kait.repo.nii.ac.jp:00001056</identifier>
        <datestamp>2025-06-23T02:50:25Z</datestamp>
        <setSpec>2:16:42:124</setSpec>
      </header>
      <metadata>
        <oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns="http://www.w3.org/2001/XMLSchema" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
          <dc:title>高周波放電を用いたイオンマイクロホンの基礎研究</dc:title>
          <dc:title>On the Study of a RF Discharge Ionic Microphone</dc:title>
          <dc:creator>秋野, 裕</dc:creator>
          <dc:creator>Akino, Hiroshi</dc:creator>
          <dc:creator>下川, 博文</dc:creator>
          <dc:creator>Shimokawa, Hirofumi</dc:creator>
          <dc:subject>ionic microphone</dc:subject>
          <dc:subject>RF discharge</dc:subject>
          <dc:subject>atmospheric plasma</dc:subject>
          <dc:subject>particle velocity</dc:subject>
          <dc:description>application/pdf</dc:description>
          <dc:description>This study examined about possibility of the ionic microphone, which works with RF discharge. RF discharge that is circuit configuration of harmonic oscillator produces plasma, and it moves at particle velocity of the sound wave. Consequently oscillation frequency deviation corresponds to the particle velocity of the sound wave. It was possible to obtain the audio signal, when the modulated signal was demodulated. This ionic microphone could response in audio frequency range. Particle velocity frequency response was higher than the ribbon microphone.</dc:description>
          <dc:description>departmental bulletin paper</dc:description>
          <dc:publisher>神奈川工科大学</dc:publisher>
          <dc:date>2010-03-20</dc:date>
          <dc:type>VoR</dc:type>
          <dc:format>application/pdf</dc:format>
          <dc:identifier>神奈川工科大学研究報告.B,理工学編</dc:identifier>
          <dc:identifier>34</dc:identifier>
          <dc:identifier>44</dc:identifier>
          <dc:identifier>49</dc:identifier>
          <dc:identifier>AN10074179</dc:identifier>
          <dc:identifier>09161902</dc:identifier>
          <dc:identifier>https://kait.repo.nii.ac.jp/record/1056/files/kkb-034-008.pdf</dc:identifier>
          <dc:identifier>https://doi.org/10.34411/00001049</dc:identifier>
          <dc:identifier>http://hdl.handle.net/10368/21407</dc:identifier>
          <dc:identifier>https://kait.repo.nii.ac.jp/records/1056</dc:identifier>
          <dc:language>jpn</dc:language>
        </oai_dc:dc>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>